SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Surgical Innovation
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Ritter, E. M.
Right arrow Articles by Smith, C. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ritter, E. M.
Right arrow Articles by Smith, C. D.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Real-Time Objective Assessment of Knot Quality With a Portable Tensiometer Is Superior to Execution Time for Assessment of Laparoscopic Knot-Tying Performance

E. Matt Ritter, MD

Emory Simulation Training and Robotics (E*STAR) Lab, Endosurgery Unit, Department of Surgery, Emory University School of Medicine, Atlanta, GA; NCA Medical Simulation Center, Norman M. Rich Department of Surgery, Uniformed Services University of the Health Sciences, Bethesda, MD.; Surgical Simulation, NCA Medical Simulation Center; Norman M. Rich Department of Surgery, Uniformed Services University, 4301 Jones Bridge Road, Bethesda, MD 20814 (eritter{at}usuhs.mil).

David A. McClusky, III, MD

A. G. Gallagher, PhD

C. Daniel Smith, MD

Emory Simulation Training and Robotics (E*STAR) Lab, Endosurgery Unit, Department of Surgery, Emory University School of Medicine, Atlanta, GA

Objective: Laparoscopic intracorporeal knot tying is a difficult skill to acquire. Currently, time to complete a knot is the most commonly used metric to assess the acquisition of this skill; however, without a measure of knot quality, time is a poor indicator of skills mastery. Others have shown that knot quality can be accurately assessed with a tensiometer, but obtaining this type of assessment has typically been cumbersome. We investigated a new method of real-time assessment of knot quality that allows for more practical use of knot quality as a performance metric. Methods: Eleven experienced endoscopic surgeons tied 100 intracorporeal knots in a standard box trainer. Each of the knots was immediately tested using the InSpec 2200 benchtop tensiometer (INSTRON, Canton MA) where a knot quality score (KQS) is generated based on the load handling properties of the knotted suture. The execution time was also recorded for each knot. Results: The assessment of all knots ended with one of two end points: knots that slipped (n = 48)or knots that held until the suture broke (n = 52). Knots that slip are generally of poorer quality than those that held. Execution time did not correlate with knot-quality score (r= 0.009, P= .9), and the mean execution time did not differ significantly between slipped and held knots (65 vs 68 seconds, P= .8). No completion time criteria were able to accurately predict slipped versus held knots. The mean KQS difference between held and slipped knots was highly significant (24 vs 12, P< .0001). A knot with a KQS exceeding 20 was nearly 10 times more likely to hold than slip. Conclusion: Time to complete a knot is a poor metric for the objective assessment of intracorporeal knot-tying performance in the absence of a measure of knot quality. Real-time evaluation of the knot quality can accurately distinguish welltied knots from poorly tied knots. This mode of assessment should be incorporated into training curriculum for surgical knot tying.

Key Words: laparoscopic intracorporeal knot tying • tensiometer • real-time assessment

Surgical Innovation, Vol. 12, No. 3, 233-237 (2005)
DOI: 10.1177/155335060501200308


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
SURG INNOVHome page
S. V Demyttenaere, P. Nau, M. Henn, C. Beck, J. Zaruby, M. Primavera, D. Kirsch, J. Miller, J. J. Liu, A. Bellizzi, et al.
Barbed Suture for Gastrointestinal Closure: A Randomized Control Trial
Surgical Innovation, September 1, 2009; 16(3): 237 - 242.
[Abstract] [PDF]


Home page
SURG INNOVHome page
N. Stylopoulos and K. G. Vosburgh
Assessing Technical Skill in Surgery and Endoscopy: A Set of Metrics and an Algorithm (C-PASS) to Assess Skills in Surgical and Endoscopic Procedures
Surgical Innovation, June 1, 2007; 14(2): 113 - 121.
[Abstract] [PDF]



Advertisement